전체 논문 목록

The off--centered TORP.

Austin DF

The American journal of otology

온라인 게재일
–
저널 발행일
1979년 7월
Vol.1 No.1, pp.19-21
PubMed 등록일
1979년 7월 1일

이 논문은 아직 한국어 요약이 없습니다.

버튼을 누르면 Gemini가 초록을 요약합니다 (20~40초). 만들어진 요약은 모든 방문자에게 보입니다.

영문 초록

Refinement of the techniques of ossicular reconstruction has provided satisfactory hearing results for a majority of patients with chronic ear disease. As documented in 1976, 16% of patients, those requiring a columneller type of ossiculoplasty because of absence of the malleus, did not realize the same degree of hearing improvement as with other types of reconstruction. These procedures, short and long "L-shaped" assemblies, used for patients without a malleus, resulted in a mean 27 dB bone-air gap postoperatively. The conclusion reached after comparison with the results obtained with other types of reconstruction was "... the L-shaped conductive system is less efficient than normal by the amount observed (27 dB). If these results are to be improved, a change in the method of reconstruction resulting in a more normal system may be required." Following duplication of the aforecited report a change in the method of reconstruction used for patients with the malleus absent was instituted, but perversely creating a less normal conductive system. This paper will present the one year results of those patients in which a Plastipore prosthesis has been used as a replacement of the previously described method and will compare these results with those of the past technique.

인용: Austin DF The off--centered TORP. Am J Otol. 1979;1(1):19-21