전체 논문 목록

Correlating Electrically Evoked Compound Action Potential Thresholds with Cochlear Implant Position Using Validated Computed Tomography-Based Electrode Localization.

Sismono F, Leblans M, Dirckx J, Zarowski A

The journal of international advanced otology

온라인 게재일
2026년 11월 19일
저널 발행일
2026년 11월 19일
Vol.22 No.6, pp.1-11
PubMed 등록일
2026년 11월 20일

이 논문은 아직 한국어 요약이 없습니다.

버튼을 누르면 Gemini가 초록을 요약합니다 (20~40초). 만들어진 요약은 모든 방문자에게 보입니다.

영문 초록

BACKGROUND: Electrically evoked compound action potential thresholds (TECAP) are quick, accessible, and objective measurements used to evaluate the electrode-to-neuron interface in cochlear implant recipients. While TECAP levels are assumed to covary with electrode position, limited sensitivity of previous electrode localization methods has thus far complicated a detailed analysis of this relationship. This study utilized high-resolution cone-beam computed tomography (CT) and a validated algorithm in order to reevaluate the relationship between electrode position and threshold profiles. METHODS: Intra-operative TECAPs and CT scans from 16 adult recipients of Cochlear Nucleus Contour Advance arrays were retrospectively analyzed. Electrode-to-modiolar wall distances (EMDs), electrode-to-Rosenthal's canal distances (ERDs) and mid-modiolar axis distances were determined and correlated with the threshold profiles. RESULTS: Linear regression analysis on a per subject basis confirmed that TECAP significantly increased with EMD and ERD. Electrode-toRosenthal's canal distances yielded higher R2 values than EMD in 13 of 16 subjects and demonstrated near-perfect correlation in 3 individuals (R2 > 0.8, P < .001). Substantial inter-subject variability was also observed in regression slopes and intercepts, which may partly reflect subject-specific neural health. A linear mixed model accounting for this variability was fitted and explained 69.4% of the total variance (R2> 0.694, P < .001). CONCLUSION: The results from this study suggest that TECAP profiles are associated with mediolateral electrode position and are possibly affected by subject-specific differences in neural health. Incorporating electrode position from specialized CT analysis algorithms into neural health measures may help isolate the neural aspects and enable novel therapeutic applications.

인용: Sismono F, Leblans M, Dirckx J, Zarowski A Correlating Electrically Evoked Compound Action Potential Thresholds with Cochlear Implant Position Using Validated Computed Tomography-Based Electrode Localization. J Int Adv Otol. 2026;22(6):1-11. doi:10.65717/iao.2026.262557