전체 논문 목록

Simultaneous Intraoperative eCAP and eABR Recordings During Cochlear Implant Surgery Reveal Complementary Neural Response Characteristics.

Schmidt FH, Oberhoffner T, Seyring D, Saur AL, Mlynski R, Zhang L

IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society

온라인 게재일
2026년 11월 12일
저널 발행일
미발행 (선게재)
PubMed 등록일
2026년 11월 12일

이 논문은 아직 한국어 요약이 없습니다.

버튼을 누르면 Gemini가 초록을 요약합니다 (20~40초). 만들어진 요약은 모든 방문자에게 보입니다.

영문 초록

OBJECTIVE: Electrically evoked compound action potentials (eCAP) and electrically evoked auditory brainstem responses (eABR) provide complementary information on peripheral and brainstem-level auditory function in cochlear implant users. Simultaneous recordings may enable efficient intraoperative assessment, but feasibility and intermodal agreement remain insufficiently characterized. METHODS: Twenty adult cochlear implant recipients were investigated intraoperatively using a unified stimulation paradigm with biphasic pulses (80 pps, 500 averages) and an extended stimulation range. eCAP and eABR (Wave V, ej5) responses were recorded simultaneously. Amplitude growth functions (AGF) were modeled using sigmoidal fits to extract threshold (THR), slope, saturation level (SLS), and saturation amplitude (AS). Intermodal correlations and polarity effects were analyzed. RESULTS: eCAP responses were detectable in 75% of cases with the combined eCAP/eABR protocol, compared with 85% using the standard automated eCAP protocol, and eABRs in 65%, with simultaneous recordings in 60%. A strong correlation was found between eCAP and eABR thresholds (R = 0.90, p < 0.001), whereas slope and saturation parameters showed weaker or no correlations. eCAP thresholds and SLS were systematically higher than corresponding eABR measures. Pulse polarity had no effect on AGF-derived parameters, but cathodic-first stimulation resulted in reduced baseline noise and slightly prolonged eABR latencies. CONCLUSION: Simultaneous intraoperative eCAP and eABR recordings are feasible and yield highly correlated threshold estimates, supporting a shared dependence on stimulus level. Differences in dynamic and temporal parameters indicate complementary sensitivity to auditory pathway function, supporting the value of combined intraoperative assessment.

인용: Schmidt FH, Oberhoffner T, Seyring D, Saur AL, Mlynski R, Zhang L Simultaneous Intraoperative eCAP and eABR Recordings During Cochlear Implant Surgery Reveal Complementary Neural Response Characteristics. IEEE Trans Neural Syst Rehabil Eng. 2026;PP. doi:10.1109/TNSRE.2026.3753044