전체 논문 목록

Hearing Preservation as a Function of Angular Insertion Depth With Manual Versus Robotic-Assisted Insertion Techniques.

Perez-Heydrich CA, Dillon MT, Quinonez Del Cid E, Broome ME, Richter ME, Scharf SP, et al.

Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology

온라인 게재일
2026년 10월 29일
저널 발행일
미발행 (선게재)
PubMed 등록일
2026년 10월 29일

이 논문은 아직 한국어 요약이 없습니다.

버튼을 누르면 Gemini가 초록을 요약합니다 (20~40초). 만들어진 요약은 모든 방문자에게 보입니다.

영문 초록

OBJECTIVE: This study reviewed the early shifts in low-frequency hearing for cochlear implant (CI) hearing preservation candidates who underwent cochlear implantation using either manual or robotic-assisted insertion of the electrode array and evaluated possible contributing factors such as angular insertion depth (AID), preoperative hearing, and age. PATIENTS: Adult CI hearing preservation candidates (≥18 yr, ≤70 dB HL at 250 Hz) who underwent cochlear implantation with a straight electrode array through a manual or robotic-assisted insertion. MAIN OUTCOME MEASURES: A low-frequency pure tone average (125, 250, and 500 Hz) was calculated from the unaided thresholds obtained preoperatively and within the initial weeks following surgery. Queried data included impedance values measured intraoperatively and at CI activation, and the AID of the most apical electrode contact. RESULTS: Of 120 cases (66 females), 92 underwent manual insertion (median age = 69.0 yrs, interquartile range = 63.5 to 79.0) and 28 underwent robotic-assisted insertion (median age = 67.0 yrs, interquartile range = 60.9 to 76.3). Patients received either a 23, 24, 26, 28, or 31.5 mm electrode array. Significantly less low-frequency pure tone average shift was observed for robotic-assisted insertions (P = 0.028), shallower AIDs (P = 0.010), and younger patients (P = 0.001). There was a significant interaction between insertion group and AID (P = 0.010), with robotic-assisted insertion demonstrating better hearing preservation at AIDs exceeding 490°. Impedance values did not differ significantly between insertion groups intraoperatively or at CI activation. CONCLUSIONS: Robotic-assisted electrode array insertion may support better early hearing preservation compared with manual insertions, particularly for patients with electrode arrays placed at deeper AIDs. LEVEL OF EVIDENCE: Level IV; retrospective cohort study.

인용: Perez-Heydrich CA, Dillon MT, Quinonez Del Cid E, Broome ME, Richter ME, Scharf SP, et al. Hearing Preservation as a Function of Angular Insertion Depth With Manual Versus Robotic-Assisted Insertion Techniques. Otol Neurotol. 2026. doi:10.1097/MAO.0000000000005108